Sunday, September 18, 2011

Magnehelic Pressure Gauge Series 2000



Mounting. A single case size is used for most ranges of Magnehelic gages. They can be flush or surface mounted with standard hardware supplied. With the optional A-610 Pipe Mounting Kit they may be conveniently installed on horizontal or vertical 1 1/4" - 2" pipe. Although calibrated for vertical position, many ranges above 1 inch may be used at any angle by simply re-zeroing.

However, for maximum accuracy, they must be calibrated in the same position in which they are used. These characteristics make Magnehelic gages ideal for both stationary and portable applications. A 4 9/16" hole is required for flush panel mounting. Complete mounting and connection fittings plus instructions are furnished with each instrument.

PHYSICAL DATA
  • Ambient temperature range: 20° to 140° F.*
  • Rated total pressure: -20" Hg. to 15 psig.+
  • Overpressure: Relief plug opens at approximately 25 psig
  • Connections: 1/8"' NPT female high and low pressure taps duplicated - one pair side and one pair back.
  • Housing: Die cast aluminum. Case and aluminum parts Iridite-dipped to withstand 168 hour salt spray test. Exterior finish is baked dark gray hammerloid.
  • Accuracy: Plus or minus 2% of full scale (3% on - 0 and 4% on - 00 ranges), throughout range at 70°F.
  • Standard accessories: Two 1/8" NPT plugs for duplicate pressure taps, two 1/8" pipe thread to rubber tubing adapter and three flush mounting adapters with screws. (Mounting and snap ring retainer substituted for 3 adapters in MP & HP gage accessories.)
  • Weight: 1 lb. 2 OZ.
  • * Low temperature models available as special option.
  • + For applications with high cycle rate within gage total pressure rating next higher rating is recommended. See Medium and High pressure options lower left.
More details will be written later.