Thursday, December 11, 2008

Ion-sensitive measuring system (ISE)

SEmax CAS40 is an ion-selective electrode system for the continuous measurement of ammonium and nitrate. The system consists of a sensor, electrodes and a transmitter (CAM40) with display and operating elements and is mounted on the basin rim. Up to two ion-selective sensors simultaneously measure the nitrate and ammonium in the activated sludge basin.

It can be applied in:



Wastewater treatment
Municipal waste water
Aeration basin for control of nitrification/denitrification processes

More details can check at the Endress Hauser website.



Thursday, November 20, 2008

Levelflex M FMP45 - ABKASJB23A2A To Be Installed at HP Heater No.8

Levelflex M FMP45 - ABKASJB23A2A To Be Installed at Hp Heater No.8

Levelflex M FMP45 - ABKASJB23A2A

Level measurement, guided radar.
High pressure/high temperature.
Application: mainly liquids.
Ideal to measure in bypass/chamber.
Setup-/diagnostic software included.
Factory precalibrated.
Reliable measuring:
:: in case of moved surface + foam
:: for changing medias
SIL declaration of conformity
A Approval: Non-hazardous area
B Process Temperature: -200...+400oC/-328...+752oF (HT)
K Probe: 1,200mm,rod 16mm, 316L
ASJ Process Connection: 3" 300/600lbs RF, 316/316L flange ANSI B16.5
B Power Supply; Output: 2-wire; 4-20mA SIL HART
2 Operation:4-line display VU331,Envelope curve display on site
3 Type of Probe: Remote, cable 3m,top entry
A Housing: F12 Alu, coated IP68 NEMA6P
2 cable Entry: Gland M20 (EEx d > thread M20)
A Additional Option: Basic version


Hardware Extern, Miscellaneous


To dismantle existing level transmitter and install new E+H High
Temperature Level Transmitter completes the following breakdown:-
a) To supply 3” spiral wound gasket #600
Qty – 1 set
b) To fabricate and supply & install stand for housing bracket
Qty – 1 set
c) To supply & install stud bolt M18x140mm SS304 c/w 2 nuts
Qty – 8 pcs
d) To fabricate, supply & install cable tray
Qty – 1 set
e) Man power, tools & equipment – 1 lot
f) Mobilize & Demobilize – 1 lot


Hardware Extern, Miscellaneous
1. To supply and install Flange Adaptor (4 holes to 8 holes)
2. ** Only apply for those chambers with 4 holes flange.

The work will be carry out by Endress Hauser Vendor by next week.

Friday, November 14, 2008

Ester Elektronik Digital Display Card Using at Generator Hydrogen Panel

Item : Digital display
Brand :Ester Elektronik
Model : PMO 5405 S4 G2
Supply Voltage : 18 Vdc~ 30 Vdc
Display height :14 mm red light.
Power supply :230V /115 AC
Outer dimension :96 x 48x120mm

Item : Digital display
Brand : Ester Elektronik
Model : PMO-2160 N3 G3 I Supply Voltage : 18 Vdc~ 30 Vdc
Power consumption : ~ 1.7 W
Type of Measurement:
Channel 1 Counting forward and backward .
Channel 2 for direction.Display : -19999 ….99999 scaling with divider and multiplier.
Power supply :230V /115 AC
Power Supply for sensor: 15 V / 60 mA

Thursday, October 30, 2008

Pepperl fuchs digital card, potentiometer card and converter card at Hydrogen Gas Panel

Pepperl fuchs digital card, potentiometer card and converter card at Hydrogen Gas Panel

Item : Digital input card
Brand : Pepperl fuchs
Model :
KFD2-SR2-EX1.W.LB
Supply Voltage: 24 Vdc~ 30 Vdc
Power consumption: ~ 1.7 W
Ambient temp: 55 C
With 3 LED light : Red LED –Power
Green LED- CHK: Yellow - Out

Item : Potentiometer Card
Brand : Pepperl fuchs
Model : KFD2- PT2-Ex1-5
Supply Voltage : 24 Vdc~ 30 Vdc
Power consumption : ~ 1.7 W
Terminal connection type : Terminal 11+ , 12 -,
Ambient temperature : 55 C

Output : 4 mA …. 20 mA

Item: Amplifier Converter Card
Brand : Pepperl fuchs
Model : KFD2-CR – Ex 1.30300
Supply Voltage : 24 Vdc~ 30 Vdc
Power consumption : ~ 1.7 W
Terminal connection type : terminal 1+, 2 -, 3, 0
Ambient temperature : 55 degree C


Saturday, October 25, 2008

Electrostatic Precipitator ESP and Pre-Heater Blow Tanks Pressure Gauges

List of WIKA Pressure Gauges:

Items: Pressure gauge
Bourdon tube pressure gauge, stainless steel series
Manufacturer: Wika
Model: 232.50
Measuring system: Stainless steel
Case: Stainless steel with pressure vent
Bezel ring:
Cam ring (bayonet type), stainless steel
Accuracy class: NS63: class 1.6; NS 100/160: class 1.0
Nominal size: 100 mm
Scale range:
0 kPa...400 kPa
Process connection: Diaphragm seal
Connector position: Lower mount
Window: Laminated safety glass
Pointer: Standard black

with integrated Alarm Contact, Electronic Sensor Series Model 830 E
first switch operation: breaks (2)
second switch operation: breaks (2)
Electrical connection: plug sidewise

Flange type: Flushed diaphragm
Model: 990.27
Process connection: ANSI 2” class 150# RF
Material of wetted parts: Stainless steel 316 series
Assembly: Direct assembly with PTFE lining
Fill fluid: KN2 Silicon oil


Items: Pressure gauge
Bourdon tube pressure gauge, stainless steel series
Manufacturer: Wika
Model: 232.50
Measuring system: Stainless steel
Case: Stainless steel with pressure vent
Bezel ring:
Cam ring (bayonet type), stainless steel
Accuracy class: NS63: class 1.6; NS 100/160: class 1.0
Nominal size: 100 mm
Scale range: -10
kPa...10 kPa
Process connection: G ½ B (male), 22mm flats
Connector position: Lower mount
Window: Laminated safety glass
Pointer: Standard black

with integrated Alarm Contact, Magnetic Snap-Action Contacts, Model 821.3, SPDT
Electrical connection: plug sidewise

Maximun contact rating with non-inductive load
Maximum voltage: 250 V
Current ratings: Make rating: 1.0 A; Break rating: 1.0 A; Continous load: 0.6 A
Maximum load: 20 W 20 VA
No of contact sets: 1
Switch version: L
Liquid filling: Glycerine 99.7%

Item: Pressure gauge
Bourdon tube pressure gauge with liquid filling and stainless steel series
Manufacturer: Wika
Model: 233.50
Design: EN 837-1
Nominal size: 100 mm
Accuracy class: NS 100: 1.0
Scale range: 0 … 15 bar
Working pressure: Steady: full scale range
Operating temperature: Ambient: -20 … + 60 °C gauges with glycerine filling
Temperature effect: When temperature of the pressure element deviates from reference temperature (+20 °C): max. +0.4 %/10K of treu scale value
Ingress protection: IP65 per EN 60 529/IEC 529
Pressure connection: Stainless steel 316L
Connector position: Lower Mount (LM); NS 100 mm: G ½ B (male), 22 mm flats
Movement: Stainless steel
Dial: White aluminium with black lettering
Pointer: Black aluminium
Case: Natural finish stainless steel, with pressure relief in case back.
Window: Laminated safety glass.
Bezel ring:
Cam ring (bayonet type), natural finish stainl. Steel.
Liquid filling: Glycerine 99.7%

Items: Pressure gauge
Bourdon tube pressure gauge, stainless steel series
Manufacturer: Wika
Model: 232.50
Measuring system: Stainless steel
Case: Stainless steel with pressure vent
Bezel ring:
Cam ring (bayonet type), stainless steel
Accuracy class: NS63: class 1.6; NS 100/160: class 1.0
Nominal size: 100 mm
Scale range: 0 … 6 bar
Process connection: Diaphragm seal
Connector position: Lower mount
Window: Laminated safety glass
Pointer: Standard black
Flange type: Flushed diaphragm
Model: 990.27
Process connection: ANSI 2” class 150# RF
Material of wetted parts: Stainless steel 316 series
Assembly: Direct assembly with PTFE lining
Fill fluid: KN2 Silicon oil


Monday, October 20, 2008

List of Instruments at SSC Hydraulics Power Packs

List of Instruments at SSC Hydraulics Power Packs

  • Items: Float switch
    Manufacturer: Fozmula
    Type: T/LL/70/9268
    HD Number: Z21049
    Electrical: Switching N/O
    Fitting: Standard 1” BSP
  • Items: Pressure Gauge
    Manufacturer: T.J Williams
    Type: 0-40Mpa 63mm ¼” bsp
    HD Number:
    016-81033-0
  • Items: Pressure Switch
    Manufacturer: Telemecanique
    Type: XML-A160-D1S11
    HD Number: Z21049
  • Items: Pressure Gauge
  • Manufacturer: T.J Williams
  • Type: 0-15Mpa 63mm ¼” bsp
  • HD Number: Z21049
  • Items: Pressure Switch
    Manufacturer: Telemecanique
    Type: XML-A500-D1S11
    HD Number: Z21049
  • Items: Pressure Transducer
  • Manufacturer: Haenni
  • Type: ED505/314.221/155 0-400 bar
  • HD Number: Z21163
  • Items: Cooler Temp. Switch
    Manufacturer: Trafag
    Type: ISNT 11015
    HD Number: Z21049
  • Items: Speed Encoder
  • Manufacturer: Hagglunds Drives
  • Type: SPLL85A-02
  • HD Number: 378-1445-813
  • Items: Pressure Gauge
    Manufacturer: T.J Williams
    Type: 0-25Mpa 63mm ¼” bsp
    HD Number: Z21049
  • Items: Denison Multifunction Proportional Valve Dual Driver
    Manufacturer: Denison Hydraulics U.K Ltd.
    Model:
    027-22070-0
  • Items: SLC500 Analog Output Card
    Manufacturer: Allen Bradley
    Model: 1746-N041
  • Items: Speed Indicator Unit
    Manufacturer: Redlion
    UK
    Part No:
    P4810000
    Dimension : 50mm x 50mm x 60mm
    Input : 4 - 20 mA
    Supply : 24 Vdc

Wednesday, October 15, 2008

Replacement of Level Transmitter mA Module for U3 Intermediate Bin

The item for the replacements are as below:

  • Item: Level Transmitter Guided level radar
  • Manufacturer: Endress + Hauser
  • Model: FMP40-AAA2GNJG21CA1
  • Certificates: For non-hazardous area
  • Probe version, material: 4mm rope, predominantly bulk solids, 316
  • Probe length: 7000 mm, 4mm rope, 316
  • Sealing: Viton O-ring
  • Process connection & material: 1 ½” NPT, 316L
  • Electronic insert/communication: 4-wire, 90…250VAC, 4-20mA
  • Display: With display VU 331 incl. on-site operation
  • Remote electronic: Standard compact device
  • Housing and cable gland/entry: Aluminium F12-housing, coated, IP68

Tuesday, October 14, 2008

Air Quality Monitoring System (AQMS) - UPS System Battery

Air Quality Monitoring System (AQMS) - UPS System Battery

Item: Rechargeable battery for UPS

Description: Valve regulated lead acid rechargable battery

Manufacturer: Yuasa

Model: NP7-12

Rating: 12V 7.0AH


Battery for the UPS System urgently required at the Air Quality Monitoring System.

Saturday, October 11, 2008

WIKA Pressure Gauge 0-160 PSI - Liquid/ Glicerin Filled

WIKA Pressure Gauge 0-160 PSI - Liquid/ Glicerin Filled

Specifications:

  • Pressure Range: 0-160 PSI
  • Size: 2" (50mm)
  • Connection: 1/4" NPT center back mount
  • Accuracy: +/- 2/1/2% of span
  • Wetted Parts: Copper Alloy
  • Case: 304 Stainless Steel
  • Window: Polycarbonate, Buna-N gasket
  • Case-to-Socket: Viton O-ring
  • Dial: White ABS plastic
  • Pointer: Black aluminum
  • Dial Layout: Numbers every 20 PSI, tick marks every 2 PSI
  • Media Temperature: 140º F maximum
  • Ambient Temperature: -4º F to 140º F


Friday, October 10, 2008

VEGAPULS68 for Bunker Level and VEGAPULS62 For Bandscreen

This is the latest 2 pieces or types new Vega Radar Level Transmitter to be check their performance since installed at our power plant. For those still blur, you can view and check what kind of these level transmitter at the related articles at the end of this post. Your comments or any shared value are welcome.

VEGAPULS68 for Bunker Level

  • Approval: ATEX II 1/2G,2G Eexd ia T5
  • Version/material: with horn antenna 316L
  • Process fitting: Process fitting/material:suit to the original diameter.
  • Electronics: four wire 4…20mA HART
  • Housing: aluminium double chamber/IP66/IP68 (0.2bar).
  • Indicating/adjustment module top mounted.
  • Communication by using VEGA special software.
  • Custom adjustment setting require

VEGAPULS62 For Bandscreen Level

  • Radar sensor for continuous level measurement with custom antenna design
  • (to meet existing application)
  • Version/material: with custom antenna design
  • Process fitting/material: suit to the original diameter.
  • Electronics: 4…20mA HART
  • Housing: Plastic
  • Indicating/adjustment module top mounted.
  • Communication by using VEGA special software.
  • Custom adjustment setting require
Related articles:


Friday, September 19, 2008

H2 Purity Gas Analyzer to be Purchase

Specifications of spare parts for ABB Hydrogen Purity System with redundancy:

P/N : 6548-001

Manufacturer : ABB Automation, UK

Replacement Hydrogen Purity and Purge Gas katharometer with redundancy,

calibrated for 3 ranges of:

85 – 100% H2 in Air,

0 – 100% Air in CO2 and

0 – 100% H2 in CO2

Output : 0 – 10mV

Power Supply : 350mA

Zero Gas : 85% H2 in 15% Air

Note : Replacement for Serial No G846802

P/N : 4234-500

Manufacturer : ABB Automation, UK

Replacement Hydrogen Purity Power Supply Unit

Output : 350mA

Power Supply : 240Vac 50Hz

Note : Replacement for obsolete model with Serial No 004234000/02

Related articles:

- ABB H2 Panel Mounted Transmitter

- Hydrogen, H2 Gas Purity System

Wednesday, September 17, 2008

ASCO Solenoid Valve New Ordering

ITEM : ASCO SOLENOID VALVE SV CUB20
MANUFACTURER: ASCO
MODEL: SCE210D001
110 VAC, 50 HZ
STAINLESS STEEL
CONNECTION SIZE : 3/8"

ITEM: ASCO AC KIT FOR SOLENOID VALVE
MANUFACTURER: ASCO
PART NO: SCE210D3N5MIB
AC KIT: C302279

ITEM: ASCO AC KIT FOR SOLENOID VALVE
MANUFACTURER: ASCO
PART NO: SCE210D022N5MIB
AC KIT: C302284

ITEM: ASCO AC KIT FOR SOLENOID VALVE
MANUFACTURER: ASCO
PART NO: SCE210D001N5MIB
AC KIT: C302273

ITEM: ASCO SOLENOID VALVE
BRAND: ASCO JOUCOMATIC
MODEL NO: G551A017MS
BODY: BLACK ANODIZIED
MAX INLET PRESS: 10 BAR
COIL: 24 VDC
CONNECTOR SPEC: DIN43650,11MM
RESPOND: SINGLE ACTING COIL
PIPE SIZE: 1/4" SIZE

ITEM: ASCO SOLENOID VALVE
BRAND: ASCO JOUCOMATIC
MODEL NO: G551A001 SL
BODY: BLACK ANODIZED
MAX INLET PRESS: 10 BAR
COIL: 24 VDC
CONNECTOR SPEC: DIN43650, 11MM
RESPOND: DOUBLE ACTING COIL / 3/2 NC OR 5/2 FUNCTION
PIPE SIZE : 1/4"

ITEM: ASCO SOLENOID VALVE
BRAND: ASCO JOUCOMATIC
MODEL NO: G551A002 SL
BODY: BLACK ANODIZIED
MAX INLET PRESS: 10 BAR
COIL: 24 VDC
CONNECTOR
CONNECTOR SPEC: DIN43650, 11MM
RESPOND: SINGLE ACTING COIL / 5/2 FUNCTION
PIPE SIZE: 1/4"

ITEM: ASCO SOLENOID VALVE 5/2 WAY
BRAND: ASCO
MODEL: SCG 551A001 MS
COIL PART: 43004886
COIL SIZE: 22
POWER RATING: 2.5W
CONNECTION: 1/4"

ITEM: ASCO SOLENOID VALVE 3 WAY VALVE
BRAND: ASCO
MODEL: 10700207
CONNECTION: 1/4" FPT
ORIFICE: 1.5MM
FLOW COEF: 1 L/MIN
COIL VOLT: 24VDC,IP65,6.9W

ITEM: ASCO SOLENOID VALVE (DOUBLE ACTING)
SOL AIR PILOT OPERATED AND RETURN (BISTABLE)
BRAND: ASCO
MODEL: G551A018MS
CONNECTION: 1/4"

VOLTAGE: 24VDC,IP65

This is the latest update list for ASCO solenoid valve only to reoder.


Monday, September 15, 2008

Fisher Valve Link Software and Fisher Hart Modem Model: Maxteck Viator (USB)

Fisher Valve Link Software
Model: VL2005 (LITE)
Communication: Hart
Initial Tags Limit: 5

Fisher Hart Modem Model: Maxteck Viator (USB)

This communicator is going to be delivered at our power plant a few days. Originally used for communicating between laptop and Fisher Valve 585C via the valve link software. I will update more later.

Related articles:

Friday, September 12, 2008

Fisher Control Valve Type 585C Servicing Report Updated

What type of servicing did this Fisher guys to the Fisher Valve?
  • Collect the machining coupling from the machine shop
  • Remove actuator
  • Install new actuator on the valve
  • Set the tubing and fittings
  • Valve calibration
  • Mount the volume tank near to the wall support
  • Perform calibration and fine tuning on the volume booster
  • Result satisfactory. Stroking speed up to 2 seconds
This is the thing they puton their report. Looks weired.... Mmm... Anyway, the valve can operate smoothly.

Wednesday, September 10, 2008

Row of Turbine or Generator

Row of Turbine at in Turbine Hall Power Station

Maybe the pic (turbine) at the back of this unit not so clear... Sorry!

Sunday, September 7, 2008

ABB TZID and TZIDC Project

Now we have some project improvement to the plant equipment. This time we are going to change some valve positioner to the ABB TZID positioner. Before this, we have the trial unit and the result is satisfied. For the starting, the list below is a part of the ABB project.

1) LP Bypass
TZID-C (Single acting, fail safe) Positioner
4-20mA Feedback signal

Installation:
  • Mounting bracket suitable for the blackborough valve
  • Installation material
  • Fitting and tubings copper material
2) Feedwater Regulator
TZID-C (single acting, fail safe) Positioner
4-20mA Feedback signal
Proximity switch N/C

Installation:
  • Mounting bracket suitable for the blackborough valve
  • Installation material
  • Fitting and tubings copper material
3) Boiler Blowdown
TZID-C (single acting, fail safe) Positioner
4-20mA Feedback signal
Limit switch

Installation:
  • Mounting bracket suitable for the blackborough valve
  • Installation material
  • Fitting and tubings copper material
4) Soot Blower
TZID Remote Positioner
4-20mA Feedback signal

Installation:
  • Mounting bracket suitable for the blackborough valve
  • Installation material
  • Fitting and tubings copper material
5) TZID-C Positioner (Spare)
V18345.10.1.0.1.2.1.00.1

(ABB SmartVision Software and LKS adapter will be include to this offer)

The rest will be updated later. So don't miss out!

Saturday, September 6, 2008

Accu-Gage Pencil Tire Pressure Gauge

  • Durable stainless steel construction
  • Easy-to-read, four-sided nylon scale, 2 psi units
  • 0-60 psi range

Friday, September 5, 2008

Cerabar S PMP75 - E+H Level Transmitter Installation

Remember 2 days ago I post about this Endress Hauser Level Sensor Transmitter Cerabar S PMP75? Remember the about the Druck 1830 level sensor transmitter I posted few months ago?

Cerabar S PMP75 - E+H Level Transmitter Installation Work

Cerabar S PMP75 - E+H Level Transmitter Installation Work

Hope you enjoy this entry and and don't forget to come back later. Any comments and suggestions are welcome.


Thursday, September 4, 2008

Apokalyptic Power Plant

Apokalyptic Power Plant



Tuesday, September 2, 2008

Cerabar S PMP75 - PMP75-ABA1HB8B3AAA CERABAR S DIGITAL PRESSURE TRANSMITTER


Cerabar S PMP75

Cerabar S with metallic measuring diaphragm and diaphragm seal. Overload-resistant and function-monitored. Communication via HART, PROFIBUS PA or FOUNDATION Fieldbus.

Areas of application

The Cerabar S pressure transmitter is used for the following measuring tasks:



Absolute pressure and gauge pressure in gases, steams or liquids in all areas of process engineering and process measurement technology
Level, volume or mass measurement in liquids
HIgh process temperature with diaphragm seals up to 350°C (662°F)
High pressure up to 700 bar

This device we replace at the Druck 1830 Level Pressure Sensor Electro Chlorination Plant. In next post, I will enlosed together with the photos during the level sensor installation.

More details about this level sensor transmitter: Click here Endress Hauser.

CruzTOOLS TirePro™ Digital Tire Pressure Gauge

CruzTOOLS TirePro™ Digital Tire Pressure Gauge

  • Compact ergonomic shape for easy pressure readings
  • Large display, with readings in 1/10 psi increments
  • Readings available in multiple scales: psi; BAR, Kpa and Kg-cm
  • Auto power off, with last-reading recall feature

Monday, September 1, 2008

Unique Pressure Gauge - Kwik Pressure Gauge

Moss Landing Power Plant

Moss Landing Power Plant



Sunday, August 31, 2008

ABB Advant Controller 31 Analog I/O Card Failure

ABB Advant Controller 31 Analog I/O 07AC91 Card

ABB Advant Controller 31 Analog I/O Card failure and effect all the Generator System. Currently problem solved by replace the faulty module 07AC91 and unit returned back in good condition.


Accu-Gage 11" Dial Tire Pressure Gauges

  • Flexible 11” hose between gauge and chuck for hard-to-reach tire valves
  • Dual range scales with psi and kPa or kg/cm are available
  • Polished brass bezel, stem and pressure release valve assembly
  • holds pressure reading until released
  • Push button valve bleeds air to desired pressure
  • 0-60 psi range

Friday, August 29, 2008

Bike Tyre Pressure Gauge

Bike Tyre Pressure Gauge

This unique pressure gauge used Digital Valve Cap - a cap with a digital readout of the current tire pressure. It’s powered by a small cell battery and activated when you press the cap.

Turbine Drain Sump Pit - Upgrading Level Probe Switch to Ultrasonic Switch Type

Project in Progress - Turbine Drain Sump Pit - Upgrading Level Probe Switch to Ultrasonic Switch Type

The previous level probe switch always giving fault signal and disturbs controlling of the water level in the system. The new type of Ultrasonic Model non-contact which expected to be more robust and reliable.

Specifications:

FDU91F-RN1A* PROSONIC S
FMU90-R11CA131AA1A* PROSONIC S

RSG30-A1A1AAA1* ECOGRAGH T

Now it is almost complete.



Thursday, August 28, 2008

PPC4 Pressure controller/calibrator

DH Instruments, a Fluke company announce the PPC4 Pressure controller/calibrator; a high performance instrument designed to provide versatility and ease of use in calibration labs and manufacturing environments. The PPC4 covers the absolute range of 1 kPa (0.15 psi) to 10 MPa (1500 psi) and gauge equivalent including very low differential pressures. PPC4’s emphasis is on high end performance, minimizing measurement uncertainty and maximizing the ranges covered by a single controller.

PPC4 Pressure controller/calibrator

Introducing:

  • Choice of new advanced local user interface with color display and point-and click navigation or economical basic interface
  • Front panel USB port with free “cockpit” software for instantaneous plug-and-play functionality with any PC
  • Real time measurement uncertainty calculation and display
  • New “F class” Q-RPT module for full scale performance at lower cost


WIKA Liquid Filled Pressure Gauge 0-160 PSI 213.53

WIKA Pressure Gauge 0 to 160 PSI

The specifications are as below:

Pressure Gauge Range: 0-160 PSI/Bar dual scale
Size: 2" (50mm)
Connection: 1/4" NPT center back mount
Accuracy: +/- 2/1/2% of span
Wetted Parts: Copper Alloy
Case: 304 Stainless Steel
Window: Polycarbonate, Buna-N gasket
Case-to-Socket: Viton O-ring
Dial: White ABS plastic
Pointer: Black aluminum
Dial Layout: Numbers every 20 PSI, tick marks every 2 PSI
Media Temperature: 140º F maximum
Ambient Temperature: -4º F to 140º F

Wednesday, August 27, 2008

Ross Liquid Filled Pressure Gauge 0-7 kg/cm2 ~ 100psi

Ross Liquid Filled Pressure Gauge 0-7 kg/cm2 ~ 100psi

Specifications:
Pressure Gauge
Manufacturer Ross
Range: 0-7 kg/cm2 ~ 100psi
Liquid Filled
Dial Gauge: 63mm
Direct Bottom Mounting

Fisher Control Valve Type 585C Servicing

Fisher Control Valve Type 585C Servicing

Today, Fisher Control Valve vendor doing their valve servicing at our power plant.

Wika Pressure Gauge At Hydrogen Pressure Control Valve

WIKA Pressure Gauge 0-60bars and 0-15bars
Used At The Hydrogen Pressure Control Valve

Monday, August 25, 2008

Kelco F25-B Series Corrosive Flow Switch

Kelco F25-B Series Corrosive Flow Switch

This is a new flow switch that we found at market and currently installed at our electrolyser ECP Stream. Alternative to Flotech ECP Flow Switch which give a lot of problems recently.

Anyway, just for your information this kind of switch already used 3 months and the result is very good and no defect from operation at all so far. If this F25-B Series Corrosive Flow Switch can be long lasting live, I would consider this one to replace the old Flotech brand flow switch. At least maybe 1 year... mmmm... what do you think?

Kelco F25-B Series Corrosive Flow Switch at Pipe

Full Specifications are as follow:

F25 SERIES CORROSIVE
RESISTANT FLOW SWITCH
BRAND : KELCO, MODEL : F25-B
DRY RED SWITCH, 240V AC 200V DC 1A

Anyone has use this product before? Please shares here. Thanks...


Saturday, August 23, 2008

Hydrogen Sensor - RKI Instrument

RKI Instrument Hydrogen Sensor

Features
  • Explosion proof housing and sensor design
  • H2 specific solid state sensor for 0 - 2000 ppm
  • H2 specific catalytic sensor for 0 - 100%LEL
  • Molecular sieve filter built in; highly specific to H2
  • Eliminates false alarms from IPA and other gases
  • 4-20 mA transmitter, 24VDC

Applications

  • Semiconductor
  • Power Plants
  • Fuel Cell Industry
  • R & D applications
  • Gas plants
This one only another options if the current Crowcon Hydrogen Monitoring System unreliable anymore.

More details you can visit RKI Instrument website.


Wednesday, August 20, 2008

WEKA Visual Level Indicator VLI

WEKA Visual Level Indicator VLI

WEKA Visual Level Indicator VLI

WEKA Visual Level Indicator VLI operating principle is based on the use of a permanent bar magnet system which ensures the safe and reliable activation of visual indication elements (flags), swithes, and transmitters, even when used on thick-wall high pressure indicator pipe.

This is what we have in our power plant which currently need to be replaced because of the britles. Then we have to upgrade the better specification instead of the old specification.

More details you can visit this WEKA website.



Sunday, August 17, 2008

Crowcon Hydrogen Leakage Detector Monitoring System - Flamgard Exe

Crowcon Hydrogen Sensor - 96HD

Crowcon Hydrogen Panel Rack

Crowcon Hydrogen Panel Display

Crowcon Hydrogen Panel (Back)

Hydrogen is highly explosive gas. All of the 7 Hydrogen detectors in our Electro Chlorination Plant (ECP) are using Crowcon Hydrogen monitoring system.

A situation lead to an extremely dangerous explosive condition if one of the ECP streams were to develop a leak and Hydrogen concentration in the building reached above the Lower Explosive Limit (LEL).

Recommended Action when the alarm appeared:

  1. Troubleshoot the reason why the detectors give an alarm. If the detectors are functioning correctly, there should not be any spurious alarms. There would not normally be Hydrogen present in sufficient quantities.
  2. Zero the detectors using compressed air and calibrate using a suitable Hydrogen calibration gas.
  3. Uninhibit the Hydrogen detection input channels and restore the system to normal operation.
Anyone that using this system facing some problems? Is this equipment Crowcon very reliable at your plant? Post and share here.


Saturday, August 16, 2008

Endress+Hauser Electromagnetic Flowmeter Promag 53 Project Update

Promag 53 Transmitter

Promag 53 Recorder and Transmitter

Promag 53 Transmitter Sensor Location

Promag 53 Sensor at the ECP Pipe

Promag 53 Recorder

Yesterday I post about the Endress+Hauser Electromagnetic Flowmeter Promag 53 Project. Now the project still in testing for around 2 weeks. If this success, we will try to install this new model to our Electro Chlorination Plant.

Friday, August 15, 2008

Endress+Hauser Electromagnetic Flowmeter Promag 53

Endress+Hauser Electromagnetic Flowmeter Promag 53

This is a new electromagnetic flowmeter delivered yesterday by Endress+Hauser personal and will be installed at the electrolyser chlorination plant pipe for flow measurement. The consequences of flow switch failure frequently and repeated recently at this electrolyser pipe which cause the Electro Chlorination Plant trip.

This situasion leads to several trial units of many brands to avoid this happen and happen again. Anyway, this one also a trial unit and if the result success will be considered.

Promag 53 Specifications

In this post, I just describe the general information of this product. Later on will include details. So make sure you will not miss my post.

Thursday, August 14, 2008

PIKOM PC Fair August 2008

14 - 16 August 2008
11:00 am - 9:00 pm
KB Mall, Kota Bharu, Kelantan
Jalan Hamzah, 15050 Kota Bharu

Pusat Dagangan Terengganu, Kuala Terengganu, Terengganu
Padang Hiliran, 21100 Kuala Terengganu

Star Parade, Alor Star, Kedah
Jalan Teluk Wanjah, 05200 Alor Star

15 - 17 August 2008
11:00 am - 9:00 pm
Berjaya Megamall, Kuantan, Pahang
Jalan Tun Ismail, Sri Dagangan, 25000 Kuantan

Vegapuls 62 Radar Level Trasmitter - Warranty Claim Done

Vegapuls 62 Radar Level Trasmitter

3 months delivered after send to Vega for warranty claim. This time is different cause from the previous one. Ready to install by today.


Related articles:

- Bandscreen Vega Radar Type Trending
- New Type of Bandscreen Level Transmitter

Tuesday, August 12, 2008

CCI Sulzer Valve and Drag Control Valve

Description: PV6
CCI Part Number: 103.215.282.001
Valve Serial Number: Valve Control

Description: Seal Set PV6
CCI Part Number: 000.101.000.783
Valve Serial Number: Valve Control

Description: SSB10-24VDC
CCI Part Number: 103.203.368.210
Valve Serial Number: Safety Unit

Description: SSB10-24VDC
CCI Part Number: 103.203.368.210
Valve Serial Number: Safety Unit

Description: Seal Set SSB10-24VDC
CCI Part Number: 103.203.368.290
Valve Serial Number: Safety Unit

Feedback Unit Complete R-SG15-4K
CCI Part Number: 103.225.224.2
Valve Serial Number: Feedback Unit

For all items above from CCI Sulzer Valve and Drag Control Valve need to reorder.


Monday, August 11, 2008

Conductivity Analyser at the Condenser Hotwell

ABB Conductivity Analyser Transmitter

This photo showing the Transmitter of Conductivity Analyser at the Condenser Hotwell. Conductivity purpose at the Condenser Hotwell are as below:

It is the cheapest and the most reliable type of analyzer which serve many function

To detect seawater ingress. Water conductivity will increase if there is seawater ingress.

To monitor condensate and feed water quality. Water conductivity will increase with the overdosing of ammonia or hydrazine.


Sunday, August 10, 2008

Bourdon Haenni 0-6 Bar Pressure Gauge


Pressure Gauge
Manufacturer: Bourdon Haenni

Part Number: EN 837-1
Type: Lower Direct Mounting
Range: 0-6 Bar

Dial gauge: 100mm

Connection: 1/4" NPT

Friday, August 8, 2008

Sample Convertion of Pressure

Sample Convertion of Pressure

Example reading: 1 Pa = 1 N/m2 = 10−5 bar = 10.197×10−6 at = 9.8692×10−6 atm, etc.

Related Posts with Thumbnails