Thursday, May 29, 2008

Turbine Blade Looks Like When Casing Removed

Turbine Blade

Thermocouple Specifications

Thermocouple I

Thermocouple II

Thermocouple III

Specifications:
- Type K
- Diameter 6mm
- 8'' length

We need to purchase a few pieces of this thermocouple...

Saturday, May 24, 2008

Show Preview ICA 2008 - KLCC

Show Preview of ICA 2008

Participants of ICA 2008

This is the brochure of ICA 2008 sent to me a few days ago.

Friday, May 23, 2008

Acid HCL Dosing Valve - Saunders Delivered

Saunders Valve

Acid HCL Dosing Valve - Saunders just delivered today. This is replacement for the Alfa Laval EC.

Friday, May 16, 2008

Pressure Gauge Looks at Electrochlorination Plant

Pressure Gauge

Pressure Gauge with diapragm or gauge guard

These are the pressure gauge photos that we take from Electrochlorination Plant. The specifications are as before.

Thursday, May 15, 2008

New Pressure Gauge to Purchase

Item : Pressure Gauge
Manufacturer : Chem Resist
Dial gauge : 4”
Connection : ½” NPT
Type : Direct bottom
Range : 0-11 bar/160 psi
Complete gauge guard PTFE diaphragms

Item : Pressure Gauge
Manufacturer : Wika
Dial gauge : 4”
Range : 0-1 bar
Fitting : 3/8"
Type : Direct bottom
Glycerin fill

Item : Pressure Gauge
Manufacturer : Wika
Dial gauge : 4”
Range : 0-4 bar
Fitting : 3/8"
Type : Direct bottom
Glycerin fill

Item : Pressure Gauge
Manufacturer : Wika
Dial gauge : 4”
Range : 0-6 bar
Fitting : 1/2"
Type : Direct bottom
Glycerin fill

All of these gauges are used at the Electrochlorination Plant and Bandscreen area.

Tuesday, May 13, 2008

How to check the Controlway Daughter board P/N: ABB-IMMFP12

How to check the DCS Controlway Daughter board P/N? : Refer to the below photo.

DCS - ABB-IMMFP12

DCS Controlway Daughter Board P/N on the above module, ABB factory mentioned that certain batch of this modules might accidentally shipped with a no good daughterboard version. That's why they need to check this serial no again and send back to the factory for their justification.

Monday, May 12, 2008

Introduction to Analyzer Monitoring System in Our Power Station

Analyzer Monitoring System

Basically this is analyzer monitoring system that we have in our power station. There are three type or system of analyzer;

1) Water Quality System
2) Combustion Emission System
3) Environment Air Quality System

After this, I will describe one by one from the above listed. Maybe I will start first for the water quality analyzer system which I familiar so much but later not in this post.

Abandoned Seaholm Power Plant Town Lake in Austin, Texas

Seaholm Power Plant Austin Texas

The Seaholm Power Plant sits on an eight-acre site on the north shore of Town Lake in Austin, Texas. The plant no longer generates power for the City. Private sector groups have recommended that Seaholm be converted to civic or cultural uses. In 1991, the City Council resolved to preserve Seaholm for public use after it is decommissioned.

Related Posts with Thumbnails