Friday, May 23, 2008
Acid HCL Dosing Valve - Saunders Delivered
Acid HCL Dosing Valve - Saunders just delivered today. This is replacement for the Alfa Laval EC.
Wednesday, March 19, 2008
Chempure CFA-1000 Sodium Analyzer
This picture was taken by me yesterday. Just want to upload the old analyzer that I have mentioned before. Sodium Analyzer at the Water Treatment Plant.
Specifications:
- Chempure Sodium Analyzer
- Scientific Instrument
- CFA-1000 Analyzer
Related article you may read;
1) Waltron Sodium Analyzer 9001 Series
Tuesday, March 18, 2008
Allen Bradley SLC 500 Power Supply Module 1746 - P2 Damaged
Yesterday, one of our instrument technician found that this power supply module 1746-P2 was defected after checking overall Water Treatment Plant System overall. At the morning, the unit operator complaint that the WTP cannot run due to some readings at the SCADA display is not correct. Earlier the indicator red light LED in front of the power supply module not ON. Tested and confirmed that the module has a problem. Change with new one then OK.
Specifications:
- Power Supply Module 120/240 VAC
- 5A @ 5VDC
- 0.96/0.20A @ 24 VDC
Specifications:
- Power Supply Module 120/240 VAC
- 5A @ 5VDC
- 0.96/0.20A @ 24 VDC
Wednesday, February 6, 2008
Endress Hauser Cerabar M PMP48
The Cerabar M PMP48 pressure transmitter measure gauge pressure at tank gauging Demin Plant. It's time to reorder the spare since the stock level at our store is low.
For more details, you can visit Endress Hauser website.
For more details, you can visit Endress Hauser website.
Monday, January 21, 2008
WTP ACID DAY TANK LEVEL MAGNETIC SWITCH FAULTY
Acid Day Tank Level Magnetic Switch faulty today as per photo below. Need to replace with the new. Try to get the original specification from the switch itself but nothing was found. Except it's brand Jola.
Tuesday, January 8, 2008
Waltron Sodium Analyser 9001 Series
Three people from Centrionics Sdn Bhd came to my office yesterday and claimed that they are local Waltron representative for this product in Malaysia . The reason why they are here is to promote their product and hopefully will be used in our Coal Fired Power Station. I enclosed here their proposal and specification for you to review.
Since we have problem on Rosemount Sodium Analyser at Water Treatment Plant and the unit not available for a long time, more than 3 agents had came to promote their products to solve the problem. Anyway, I ask them to give us full quotation and their proposal should be completed properly before submitting to management level to be reviewed.
Since we have problem on Rosemount Sodium Analyser at Water Treatment Plant and the unit not available for a long time, more than 3 agents had came to promote their products to solve the problem. Anyway, I ask them to give us full quotation and their proposal should be completed properly before submitting to management level to be reviewed.