Friday, May 23, 2008

Acid HCL Dosing Valve - Saunders Delivered

Saunders Valve

Acid HCL Dosing Valve - Saunders just delivered today. This is replacement for the Alfa Laval EC.

Wednesday, March 19, 2008

Chempure CFA-1000 Sodium Analyzer

This picture was taken by me yesterday. Just want to upload the old analyzer that I have mentioned before. Sodium Analyzer at the Water Treatment Plant.

Chempure CFA-1000 Sodium Analyzer

Specifications:
- Chempure Sodium Analyzer
- Scientific Instrument
- CFA-1000 Analyzer

Related article you may read;
1) Waltron Sodium Analyzer 9001 Series

Tuesday, March 18, 2008

Allen Bradley SLC 500 Power Supply Module 1746 - P2 Damaged

Allen Bradley SLC 500 Power Supply Module 1746-P2 Damaged

Yesterday, one of our instrument technician found that this power supply module 1746-P2 was defected after checking overall Water Treatment Plant System overall. At the morning, the unit operator complaint that the WTP cannot run due to some readings at the SCADA display is not correct. Earlier the indicator red light LED in front of the power supply module not ON. Tested and confirmed that the module has a problem. Change with new one then OK.

Specifications:
- Power Supply Module 120/240 VAC
- 5A @ 5VDC
- 0.96/0.20A @ 24 VDC

Wednesday, February 6, 2008

Endress Hauser Cerabar M PMP48

The Cerabar M PMP48 pressure transmitter measure gauge pressure at tank gauging Demin Plant. It's time to reorder the spare since the stock level at our store is low.

For more details, you can visit Endress Hauser website.

Monday, January 21, 2008

WTP ACID DAY TANK LEVEL MAGNETIC SWITCH FAULTY

Acid Day Tank Level Magnetic Switch faulty today as per photo below. Need to replace with the new. Try to get the original specification from the switch itself but nothing was found. Except it's brand Jola.


Need to get a new brand from local supplier and easy to purchase. Anyway, we still have three spares at the store before everything finish and have the time to manage.

Tuesday, January 8, 2008

Waltron Sodium Analyser 9001 Series

Three people from Centrionics Sdn Bhd came to my office yesterday and claimed that they are local Waltron representative for this product in Malaysia. The reason why they are here is to promote their product and hopefully will be used in our Coal Fired Power Station. I enclosed here their proposal and specification for you to review.

Waltron sodium Analyser Proposal
Waltron sodium Analyser Specification

Since we have problem on Rosemount Sodium Analyser at Water Treatment Plant and the unit not available for a long time, more than 3 agents had came to promote their products to solve the problem. Anyway, I ask them to give us full quotation and their proposal should be completed properly before submitting to management level to be reviewed.