The Real Instrumentation and Process Control Engineering Blog Purposely Built for Education.
"Introducing the world’s first fieldbus calibrator
The MC5 Fieldbus Calibrator is a combination of a multifunction calibrator and a fieldbus configurator. The MC5 is a compact, easy-to-use and field compatible calibration solution that offers a lot of functionality. The fieldbus functionality of MC5 includes reading the digital output of the fieldbus transmitter, changing the configurations of transmitters and transmitter trimming. Calibrating fieldbus transmitters with the MC5 requires only one person and the calibration results are automatically documented.
Main features:
• Calibrate Foundation Fieldbus H1 or Profibus PA transmitters
The photo that you see above is a common color that available in the market. But have you seen the pink color of Beamex MC5 Calibrator before?"
• The MC5 is a calibrator and a fieldbus configurator in one unit
• The MC5 makes traceable calibrations
• Calibration results are automatically documented in the MC5
• A compact, easy-to-use and field compatible calibration solution
• The MC5 Fieldbus Calibrator can be used for various other calibrations as well
I am sure you never see this color before. But I am not sure whether this fancy color is in the market or not. Try to contact your supplier to know more about this. Mmmm...
Again, this morning operation raised defect to us on Electro Chlorination Plant (ECP) flow switch problem. After a few days switch has been installed with minor modification on the probe; new spring changed to stainless steel and the flapper is coated with anti-oxide hoping that the lifetime can be longer than before, but the result frustrated. There is already a few times I mentioned in this blog that the unreliable flow switch urgently needs to be replaced as the ECP Cell downtime very frequently happened.
Recently, Vega and Endress Hauser tested their probes on the ultrasonic type. It took one week to complete in January. The tuning of the parameters has been done for a few times to get a good result but at the last stage it failed. The reason it failed is the flow rate is not stable due to two medium mixture, water and air bubbles. In this case, air bubbles will absorb the signal from the ultrasonic then cause the reading fluctuating. At the end, they would like to trial another type of measurement either magnetic or different pressure DP type. But I am still waiting for them to their recommendation which has been promised in February.
Me? I am not interested to celebrate this event. Everyday you can show love and caring to your couples. Why people wait this event to show and express their love? And people who are too excited will spend so much money. Whatever la, happy getting angry when your lover not wishing you this Valentine’s Day. And also happy crying when no one sends you any roses. Haha….
After doing some checking, not enough air pressure to close the control valve from the volume booster. The function of volume booster is to boost big volume air to the valve diaphragm either fast closing or fast opening. Servicing done for all volume booster HP Heater and reading back to normal operation.